Code Blue
259 Hedcor Street
Holland, MI 49423 USA
800.205.7186
www.codeblue.com
GU-137-Hpage 40 of 67
IP1500 and IP2500 Series
Administrator Guide
ACTION SCRIPT PARAMETERS
WithintheScriptsaremanysettingscontrollingthenextstepintheprocessoftheActionScript:Du-
rationoftheprocess,Enable/Disablefeatures,orevenareactivationofanAuxOutputwithatimed
limitation.ThefollowingwillprovidedetailedexplanationsintotheseScriptcontrols.
Note:Scripts,PhoneNumbersandRecordingsallsharea1Mbmemorycap.
Playing a Message
MessagescanbesettoplayanytimeupontheactivationofaScriptorduringacall.
Plus,theycanbesettorepeatasshownhere:
Place Call
Placing a Calliswheretheadministratorsetsupwhichnumberswillbeattemptedandtheorder.
Theadministratorcouldchoosemultiplenumbersstoredin“Numbers”orthesamenumbercanbe
repeatedmanytimes.“Ifnotanswered,then”Call.Selectadditionalnumberstobedialed.
Dialing/Answer Timeout:Thedefaulttimeis60secondsandcanbesteppeddowntoaslittleas
veseconds,beforethecallattempttimesout.
Maximum Call Duration: Thedefaulttimeis600seconds(10minutes).Durationrange0001to
9999seconds(1secondupto166.65minutes).Thirtysecondsbeforethetimerexhaustsanaudible
tonewillplaytonotifybothpartiesthecallisabouttoterminate,unlessthetimerisdisabledthrough
aDuringcallCommand(DTMFtone3).
While Dialing:StandardRingbackisthedefaultsetting.Otherchoices:Amessagecanbesetto
playtothepersonattheIP1500/2500and/orDoNothing,untilthecallisconnected.