3. Check for Stored Energy: At the applicator, press the “Air-Only” once, pull the trigger. No activity
should be present at the machine.
4. Isolation Verification: Does the machine have electric power or compressed air present? The
power button should not be lit; it should be off. The HMI display should have no images present.
At the applicator, press the “Air-Only” once, pull the trigger. No activity should be present at the
machine.
5. Verify the reason for using the Lockout Tagout procedure has been solved. Once you
verify that the problem is solved, follow the instructions in the Starting the Machine section of
this manual.
Emergency Stop
CAUTION - Do not use the Emergency Stop button to shut down the
machine for anything other than an emergency.
The Emergency Stop button is used if the machine must be shut down immediately.
If any event occurs that could cause harm to personnel or equipment, then use the Emergency
Stop to shut down the machine.
The Emergency Stop button is a push button. Once pushed, the button becomes locked in the
down position. The button must be rotated clockwise to reset. Once rotated, the button will pop
outward to its ready state. The display on the machine will show the Reset Screen. See Reset
Screen section for instructions on how to use the machine again.
NOTE: When the machine is in idle, such as between cleaning cycles, the machine has full power
to all functions and motors.
NOTE: When the Emergency Stop has been activated, there is only power going to the control
board and safety relay. Nothing on the machine will operate until the Emergency Stop has been
reset.