PROBLEM CAUSE SOLUTION
When the switch on the
CBM module is pressed,
the EVERFLO motor pump
does not start or stop during
operation.
The system's protection fuse has
blown.
Replace the fuse.
In the event of further intervention,
do not use the machine and contact a
SPECIALIST TECHNICIAN
.
The motor pump protection fuse
has blown.
Replace the fuse.
In the event of further intervention,
do not use the machine and contact a
SPECIALIST TECHNICIAN
.
The battery is at. Recharge the battery.
The pump does not prime. Air suction. Check the integrity of the suction
circuit.
Regulation valve (27) positioned
under pressure.
Reset the pressure by rotating the
knob (20) counter-clockwise, setting
the pump to
“BYPASS”
.
Filter knob (24) with valve absent
or badly engaged.
Insert the knob back into the lter and
ensure it is correctly positioned (refer
to section
“FILTER CLEANING.
The pump does not reach
the maximum pressure.
Pressure regulation knob (20)
insuciently screwed in.
Rotate the knob clockwise until the
desired pressure is reached.
Suction circuit with bottlenecks. Check the suction circuit (especially
check that the suction lter is clean).
Nozzle worn or too large. Replace the nozzle (refer to the section
“OPERATION”
.
Irregular pressure or ow
(buttons).
Air suction. Check the integrity of the suction
circuit.
Dirty suction lter. Clean lter.
The motor pump did not
complete priming.
Prime the pump as described in the
section
“OPERATION”
.
Accentuated noise. Suction circuit with bottlenecks. Check the suction circuit (especially
check that the suction lter is clean).
High delivery water temperature. Observe the temperatures listed in the
section
“SPECIFICATIONS AND TECHNICAL
DATA”
.