D-2 Diagnostic Error Codes
Tables D-2 through D-18 list possible error codes, descriptions of each error condition, and actions
required to resolve the error condition.
Retest the system after completing each step. If the problem has been resolved, do not proceed
with the remaining steps.
For assistance in the removal and replacement of a particular subassembly, see Chapter 5, "Removal
and Replacement Procedures."
Table 4-2
Microprocessor Test Error Codes
Error
Code Description Recommended Action
0101-xx CPU test failed. Replace the system board and retest.
0102-xx Coprocessor error.
1. Run Computer Checkup or Computer Setup and retest.
2. Replace the system board and retest.
0103-xx DMA controller failed. The following step applies to error codes 0103-xx through 0106-xx.
0104-xx Interrupt controller failed. Replace the system board and retest.
0105-xx Port error.
0106-xx Keyboard controller self-test failed.
0107-xx CMOS RAM test failed. The following steps apply to error codes 0107-xx through 0109-xx:
0108-xx CMOS interrupt test failed.
1. Replace the battery/clock module and retest.
0109-xx CMOS clock test failed.
2. Replace the system board and retest.
0110-xx Programmable timer test failed. The following step applies to error codes 0110-xx through 0113-01:
0113-01 Protected mode test failed. Replace the system board and retest.
0114-01 Speaker test failed.
1. Verify the speaker connection.
2. Replace the system board and retest.