Compaq Deskpro 4000S and 4000N Personal Computers 2-19
Keyboard Light Combinations
The table below lists the keyboard light combinations along with the meaning and actions associated
with each combination.
Table 2-6
Keyboard Light Combinations
Num Lock Caps Lock Scroll Lock Meaning and Required Action
OFF ON OFF System requires setup password.
Enter the setup password. The light remains on until you enter
a valid setup password.
ON OFF OFF System could not start from a diskette because the ROMPaq
diskette is not present, is bad, or the drive is not ready.
Turn off the power, insert a valid ROMPaq diskette, then turn on
the power.
OFF OFF ON ROM upgrade failed.
Try another ROMPaq diskette. If the light remains on, contact
Compaq customer support.
ON ON ON ROM upgrade successfully completed.
Turn power off and back on to resume normal system
operation.
2.9 Compaq Intelligent Manageability
The Local Alert Pop-Up Dialog notifies you of an impending or actual hardware failure. It the
computer is connected to a network and the Compaq Insight Management Desktop Agents are
installed and configured, an SNMP trap (message) is sent to the specified SNMP-compliant
management application.
The Local Alert Pop-Up Dialog also tells you the steps you need to take prior to a hardware failure to
avoid loss of data and damage to the computer. The system administrator can create a customized
action message that might include contact telephone or pager numbers.
To close the Local Alert Pop-Up Dialog, click the Close button. To retrieve fault information after
closing the dialog, run Compaq Insight Personal Edition.
For more detailed information, refer to the online Intelligent Manageability Guide or Remote
Management Administrator’s Guide. Additional information is available in the Compaq Insight
Manager Users Guide.