EasyManua.ls Logo

Control Techniques Commander SE Series

Control Techniques Commander SE Series
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commander SE User Guide
28 Issue Number 5
Table 4.7 Drive Range: SE23200400, three phase
Commander SE Size 3
Table 4.8 Drive Range: SE33200550 to SE33200750
Table 4.9 Drive Range: SE33400550 to SE33400750
Commander SE Size 4
Table 4.10 Drive Range: SE43401100 to SE43401500
Key:
R EN50081-1 Conducted emission requirements of the generic emission standard
for the residential, commercial and light industrial environment.
I EN50081-2 Conducted emission requirements of the generic emission standard
for the industrial environment.
# Special techniques required e.g. output filters. Contact your Local Control
Techniques Drive Centre.
Motor cable
length
m
Filter and Switching Frequency
Standard
(4200-6203)
Low Cost
(4200-6303)
Low Leakage
(4200-6209)
3kHz 6kHz 12kHz 3kHz 6kHz 12kHz 3kHz 6kHz 12kHz
20
III
45
I##
100 I # #
Motor cable
length
m
Filter and Switching Frequency
Standard
(4200-6302)
Low Cost
(4200-6303)
3kHz 6kHz 12kHz 3kHz 6kHz 12kHz
15
II#
100 I # #
Motor cable
length
m
Filter and Switching Frequency
Standard
(4200-6301)
Low Cost
(4200-6304)
3kHz 6kHz 12kHz 3kHz 6kHz 12kHz
15
III
100 I # #
Motor cable
length
m
Filter and Switching Frequency
Standard
(4200-6401)
Low Cost
(4200-6402)
3kHz 6kHz 12kHz 3kHz 6kHz 12kHz
15
I##
100 I # #

Related product manuals