If the Mode key is pressed and held down for 2 seconds, the display’s status
mode will change from the speed indication to the load indication and vice
versa (see parameters 22 and 23).
Multiplying factor on motor speed (rpm) to give customer defined units
Used to set up a user security code.
OFF - Keypad Forward / Reverse key disabled
On - Keypad Forward / Reverse key enabled
In keypad control, this parameter selects the value of the keypad reference on power-
up.
0 keypad reference is zero
LASt keypad reference is last value selected before the Drive was powered down.
PrS1 keypad reference is copied from preset speed 1.
In keypad control, to look at the keypad reference with the Drive disabled, press the
and keys together.
In terminal control, to look at the keypad reference, press either the or key.
Any parameter values that have been changed via serial communications but
not stored in the Drives EEPROM memory will not be stored in the Quickey.
NOTE
No. Function Type Limitations Range Units Defaults
24
Customer
defined
scaling
RW U 0 - 99.99 1.00 EUR
1.00 USA
No. Function Type Limitations Range Units Defaults
25
Security
set up
RW U, S 0 - 9999 0 EUR
0USA
No. Function Type Limitations Range Units Defaults
26
Fwd/Rev
key enable
RW Bit On, OFF OFF EUR
OFF USA
No. Function Type Limitations Range Units Defaults
27
Power up
keypad ref.
RW T 0, LASt,
PrS1
0EUR
0USA
No. Function Type Limitations Range Units Defaults
28
Parameter
transfer
Quickey
RW T, R no, rEAD,
Prog, Auto, boot
no EUR
no USA
no Do nothing
rEAd When this is set and the user performs a Drive reset by pressing the STOP/
RESET key while the Drive is disabled (ih), tripped (tr) or on stand-by (rd),
the Quickey contents will be copied to the Drive and parameter 28 reset to
no. These parameters are then saved automatically by the Drive.
Prog When this is set and the user performs a Drive reset by pressing the STOP/
RESET key, the Quickey contents will be updated with the current Drive
EEPROM memory parameter settings. Parameter 28 is also reset to no.