EasyManuals Logo

Control Techniques M'Ax 406 User Manual

Control Techniques M'Ax 406
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
*
66 M’Ax User Guide
Issue Number: 4
Parameter
Range(
ô
)Default(
ð
)
Type
6.01 Stop mode selector 0~2 2 RW Txt P
6.03 ac supply loss mode selector 0 ~ 1 0 RW Uni P
6.08 Hold zero speed select 0~1 1 RW Bit
6.15 Drive enable 0~1 1 RW Bit
6.20 Powered-up time (years, days) 00.00 ~ 9.365 y.d
RO Uni S P
6.21 Powered-up time (hours, minutes) 00.00 ~ 23.59 h.m
RO Uni S P
6.31 Sequencing bit JOG FORWARD 0 ~ 1 0 RW Bit
6.32 Sequencing bit JOG REVERSE 0 ~ 1 0 RW Bit
6.33 Sequencing bit FORWARD/REVERSE 0 ~ 1 0 RW Bit
6.34 Sequencing bit RUN 0 ~ 1 0 RW Bit
6.35 FORWARD LIMIT switch 0 ~ 1 0 RW Bit
6.36 REVERSE LIMIT switch 0 ~ 1 0 RW Bit
6.44 Active supply indicator 0~1
RO Bit
6.48 DC-bus threshold voltage 0 ~ 600 400 RW Uni
6.49 Controlled-stop enabled indicator 0~1
RO Bit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques M'Ax 406 and is the answer not in the manual?

Control Techniques M'Ax 406 Specifications

General IconGeneral
BrandControl Techniques
ModelM'Ax 406
CategoryServo Drives
LanguageEnglish

Related product manuals