message
•
Previous error no longer exists e.g. not
enough water or excessive temperature (the
actual error can be queried in the logbook)
ID=33
in
steam generator
(water level could
not be reached
within 3 minutes)
•
Soft water connection not connected to
water supply
•
Dirt filter in the solenoid valve or in the mains
water connection dirty
•
Water level sensor calcified (insulated) or
defective
•
Through the use of non-original
CONVOTHERM cleaners, foaming in the
steam generator and insulating film on double
level sensor
•
Filling gap in the steam generator is closed
by calcium deposits
•
Water conductance too low through
softening
•
Solenoid valve Y3 faulty
•
Injection nozzle in non-return device blocked
•
Steam generator calcified
•
Contact problems between steam generator
and housing (earth connection)
•
Contact problems between water level
sensor and terminal strip X15 of the control
ID=33
(water pressure
below 0.5 bar 3
seconds after
valve switched
through)
•
Solenoid valve Y4 faulty
•
Pressure switch S1 defective
•
Dirt filter in the solenoid valve or in the mains
water connection dirty
•
T-piece for pressure switch / manometer or
injection nozzle in water supply blocked /
dirty Clean with needle
•
Contact problems between pressure switch
and terminal strip X15 of the control module
•
Appliance not connected to soft water and
therefore inlet calcified
slowly
•
Filling time of steam generator too long;
Possible cause: Water supply not completely