Excessive
temperature in the
wiring space
At a temperature >
45°C the auxiliary fan
is switched on. Error
threshold at 80°C
Fan runs permanently
in the OGB and OGS.
•
Vent slits blocked by an inadequate space
between appliance and wall
•
Air supply blocked
•
Minimum distance to heat sources not
observed
•
+ and - of the 12 V auxiliary fan reversed
Fan malfunction
(excessive
temperature in the
motor winding)
!
thermoprotection
contact has
tripped
•
Fan motor M1/M2 has excessive
temperature in the winding
a) One phase is missing from the power
connection
b) Fan motor is defective
c) One phase is not connected through from
the
contactor
d) Microfuse F10 (6.3 A or 10 A for
floor models) has tripped
e) Thermoprotection contact in the motor
winding
(bi-metallic strip) defective or interrupted
Auxiliary fan
malfunction
Motor current too
high etc.:
threshold of 1.5A
(V1-V2)
•
Auxiliary fan fault
•
Auxiliary fan wiring interrupted
•
Auxiliary fan blocked
Oven sensor (B6
thermoelement)
excessive
temperature
(temperature on
the sensor
>300°C)
•
Hot air contactors do not switch off (burnt
together)
•
Motor not operating (e.g. because of 2
defective microfuses F10.
Core temperature
sensor 1 -
excessive
temperature
•
Temperature of CTS sensor already higher
than the maximum possible desired value
(sensor not inserted into food correctly)
Core temperature
sensor 2 -
excessive
temperature
•
Temperature of CTS sensor already higher
than the maximum possible desired value
(sensor not inserted into food correctly)
Core temperature
sensor 3 -
excessive
temperature
•
Temperature of CTS sensor already higher
than the maximum possible desired value
(sensor not inserted into food correctly)
Core temperature
sensor 4 -
excessive
temperature
•
Temperature of CTS sensor already higher
than the maximum possible desired value
(sensor not inserted into food correctly)