2C9-6.0
1-4-3
Optical U093 Setting the exposure density gradient
Text/text and photo/photo mode 0/0/0
U099 Checking the original size detection -
High voltage U100 Setting the main high voltage
Grid control voltage
Copy interval
Copy quantity
Correction amount
135
60
50
10
U101 Setting the other high voltages
Developing bias clock frequency
Developing bias clock duty
Transfer control voltage (large size)
Transfer control voltage (small size)
Transfer charging output OFF timing
Transfer charging output ON timing
Separation control voltage
Separation charging output ON timing
Separation charging output OFF timing
27
45
168
179
37
36
1
35
42
U110 Checking/clearing the drum count -
Developing U130 Toner install mode -
U144 Setting toner loading operation Off
U157 Checking/clearing the developing drive time -
U158 Checking/clearing the developing count -
Fixing and
cleaning
U161 Setting the fixing control temperature
Primary stabilization fixing temperature
Secondary stabilization fixing temperature
Copying operation temperature 1
Copying operation temperature 2
Number of sheets for fixing control
Number of sheets for fixing control (thick paper)
140
160
170
180
5
20
U162 Stabilizing fixing forcibly -
U163 Resetting the fixing problem data -
U167 Checking/clearing the fixing count -
U199 Checking the fixing temperature -
Operation
panel and
support
equipment
U200 Turning all LEDs on -
U202 Setting the KMAS host monitoring system -
U203 Operating DP separately -
U204 Setting the presence or absence of a key card or key counter Off
U207 Checking the operation panel keys -
U243 Checking the operation of the DP motors and solenoids -
U244 Checking the DP switches -
Mode setting U250 Setting the maintenance cycle 150000
U251 Checking/clearing the maintenance count 0
U252 Setting the destination Japan
U253 Switching between double and single counts A3
U254 Turning auto start function on/off On
Section
Item
No.
Content of maintenance item
Initial
setting*
*Initial setting for executing maintenance item U020