2C9-6.0
1-4-4
Mode setting U255 Setting auto clear time 90
U258 Switching copy operation at toner empty detection Single mode
U260 Changing the copy count timing After ejection
U265 Setting the destination specifications 0
U332 Setting the size conversion factor 1.0
U342 Setting the ejection restriction On
U343 Switching between duplex/simplex copy mode Simplex copy
U344 Setting preheat/energy saver mode ENERGY STAR
U345 Setting the value for maintenance due indication -
Image
processing
U402 Adjusting margins of image printing -
U403 Adjusting margins for scanning an original on the contact
glass
-
U404 Adjusting margins for scanning an original from the DP -
U407 Adjusting the leading edge registration for memory image
printing
-
Other U901 Checking/clearing copy counts by paper feed locations -
U903 Checking/clearing the paper jam counts -
U904 Checking/clearing the service call counts -
U905 Checking/clearing counts by the DP -
U908 Checking the total count -
U910 Clearing the black ratio data -
U911 Checking/clearing copy counts by paper size -
U927 Clearing accounting counter -
U928 Checking the machine life counts -
U941 Setting the default magnification ratio of the default cassette 100%
U942 Setting of amount of slack for feeding from DP 0/0
U990 Checking/clearing the time for the exposure lamp to light -
U991 Checking the scanner count -
U993 Outputting a VTC-PG pattern -
Section
Item
No.
Content of maintenance item
Initial
setting*
*Initial setting for executing maintenance item U020