42 - ORDINARY MAINTENANCE
COROB™ D600 - D700 - D800 EXTRA
1. Disconnect power supply (chapter 5.8).
2. Screw tool A to puncher B.
3. Insert wrench C in the tool slots and slightly loosen screws D (do not unscrew them completely).
4. Rotate and pull down tool A, so as to remove puncher B, then separate the puncher from the tool.
5. If necessary, clean the surfaces of the puncher to remove encrusted matter, using a product compatible
with the type of bases used in your system. We recommend lubricating the puncher walls with a common,
non-contaminant lubricant (ENOTAP or similar).
6. Reassemble the puncher following the above steps in reverse order.
7. Connect power supply and switch on the machine (chapter 5.3).
If the can punching is inadequate because the cutting edge of the puncher is excessively worn, replace the
worn puncher.
7.8 Relling the humidier system bottle
WARNING
When the water in the bottle reaches the minimum level, ll up immediately.
1. Disconnect power supply (chapter 5.8).
2. Open the machine upper cover where the bottle is located.
3. Unscrew the bottle cap and add water (1 Pint / 0.5 liters maximum), paying attention NOT TO EXCEED THE
MAXIMUM LEVEL.
To reduce the risk of lime encrustations due to hard water, it is recommended to use distilled water.
4. Replace the cap and rmly tighten.
5. Close the upper cover, connect power supply and switch on the machine (chapter 5.3).
2 3
MAX
MIN
MAX
MIN
MAX
MIN
5
0
0
m
l
1
P
i
n
t
MAXMAX
MIN
MIN
Figure 27