Questions and Answers

  • D
    David MullinsAug 11, 2025
    Why won't my corob PROsample 200 Dispenser turn on?
    • H
      Hannah BurtonAug 11, 2025
      If your corob Dispenser doesn't turn on, there are several potential causes: * A missing power supply: Check the connections at the back of the machine. * The main switch is in the OFF position: Set the main switch to the ON position. * Blown fuses: Replace any blown fuse inside the fuse compartment. * The power supply unit is in overcurrent: Wait a few minutes and try to restart the machine. If the problem persists, contact the authorized technical service. * Defective electrical connections: Contact the authorized technical service.
  • C
    Christopher SampsonAug 18, 2025
    What to do if corob PROsample 200 Dispenser software shows a communication error?
    • A
      Alexandra GonzalesAug 18, 2025
      If the management software indicates a communication protocol error with your corob Dispenser, consider these possible causes and solutions: * The machine is OFF: Turn the machine on and restart the management software. * The machine is disconnected from the computer: Check the connections at the back of the machine. * The computer serial port or USB port is wrongly configured or defective: Use the configuration and calibration software to ensure the port used to communicate with the machine is correctly configured. Repair the computer serial port or USB port. * The serial cable is damaged: Replace the communication cable using manufacturer’s original spare parts. * Connection defective: Contact the authorized technical service.
  • S
    Stephen ShortAug 23, 2025
    How to fix colorant dripping from corob PROsample 200 Dispenser nozzles?
    • A
      Alex GomezAug 23, 2025
      If you notice colorant dripping from some nozzles on your corob Dispenser, it may be due to the valve of the pumping unit not working correctly. To resolve this, dispense approximately 100 cc of colorant from the affected pumping unit using the management software. If multiple circuits are involved, repeat this process one circuit at a time to recycle the dispensed colorant. If the issue continues, contact the authorized technical service.
  • S
    Samantha DiazAug 29, 2025
    What does it mean if the ON lamp blinks slowly on my corob Dispenser?
    • K
      kendra89Aug 29, 2025
      If the ON lamp on your corob Dispenser blinks slowly and the machine is unresponsive to commands, it indicates that the machine is in the offline 1 condition. To fix this, bring the machine to the online condition by using the offline button or by sending a Reset command.
  • C
    Carlos CharlesSep 4, 2025
    Why is the ON lamp blinking fast and the corob PROsample 200 Dispenser not working?
    • A
      Ashley WyattSep 5, 2025
      If the ON lamp on your corob Dispenser blinks rapidly and the machine does not respond to commands, it means that the Autocap is open and the machine is in the offline 2 condition. To resolve this, close the Autocap and bring the machine to the online condition by using the offline button.