Released on 10/31/05 - X800058A UV Pure Technologies Inc. © 2005
No part of this document may be photocopied, reproduced, transmitted, or translated to another language without the
prior written consent of UV Pure Technologies Inc.
For additional info call 1-888-407-9997 or email info@uvpure.com
or visit www.uvpure.com
33
21
22
C300075 INSERT ADAPTER FOR FLOW REGULATOR
1
C300055
C300012
C300017
Part No.
E100034
C500000
C300058
E300142
E300108
C300056
E300153
C300051
18 650066
17
65000016
8
19
14
12
35001111
10
3500079
3500097
3500146
5
4
2
3
Item
1
SHAFT RETAINING RING
MOTOR & MTG PLATE ASSY
BRACKET FASTENER, 1/4-20x5/8"LG
1
1
8
TOP END CAP ASSY - 1" C/W SHAFT GUIDE
WASHER, TEFLON, 5/8" ID X 1" OD
1
SEAL WASHER FOR 1" FLEXIBLE HOSE
1" FIP FLEXIBLE HOSE
WIPER & SHAFT ASSY
BEARING O RING SEAL
BEARING & BASE, WIPER SHAFT
U-CUP SEAL FOR WIPER
4
2
1
1
1
1
BRACKET - TOP, PLAIN END
WIPER O RING SEAL
QUARTZ O RING SEAL
BTM END CAP ASSY - MOTOR END
BRACKET - BTM, MOTOR END
1
2
1
1
QUARTZ SLEEVE
1
1
1
Parts List For Hallett 30
Qty
Description
13 C300076 1 FLOW REGULATOR, 30 USGPM
15 650001 8 1/4" LOCK WASHER
20
E600036
1
VIEW A
5
9
10
11
6
20
4
22
13
12
7
8
19
6
2
1
15
16
14
3
18
A
17
RUBBER WASHER FOR MOTOR SHAFT
650099
21 1
FOAM PAD FOR MOTOR
Figure 4B – Hallett 30
Step 1:
Fill a bucket or container with water before shutting off the water supply
since you will need the water later to clean the quartz sleeve (3). A squeeze
bottle is useful for applying water or cleaning solution
to the inside of the quartz
sleeve.
Step 2: Place another bucket under the unit and drain the unit (see Draining the
Unit).
Step 3: Open the unit and remove the lamps (see Determining the Need for
Cleaning).