Electrical System
107
Stopped: Seat switch fault
/ Check to see if seat is
plugged in / Restart, if
problem persists contact
service
Fault Disables Blades and Drive Interlock1
code 8
code 16
code 24
Dual seat switch inputs
are not equal
Poor connection, faulty
switch, damaged harness
Stopped: Seat switch fault
/ Check to see if seat is
plugged in / Restart, if
problem persists contact
service
Fault Disables Blades and Drive Interlock1
code 8
Detected one or more
motors not slowing down
after seat switch opened
Blades Off: PTO switch
fault / Restart, if problem
persists contact service
Fault Disables Blades Interlock 2
code 1
Dual PTO switches not
matched
Poor connection, faulty
switch, damaged harness
Stopped: Brake sensor
fault/ Restart, if problem
persists contact service
Fault Disables Blades and Drive Brake sensor rises to or
near 5v
Faulty brake switch, poor
connection or a damaged
harness
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger Possible causes