Curtis 1243GEN2 Manual
46
3 — PROGRAMMABLE PARAMETERS:
Hourmeters
Once the preset values have been loaded, the Set Total Hours parameter
should be programmed Off.
SET TRAC HRS
The set traction hours parameter is used to apply preset high, middle, and low
values to the traction hourmeter. First, adjust the preset values as desired for the
traction hourmeter. Then, program the Set Traction Hours parameter On,
which automatically loads the preset values. Once they have been loaded, the Set
Traction Hours parameter should be programmed Off.
SRVC TOTL HRS
The total service hours parameter is used to set the timer for the next scheduled
overall maintenance. The service interval can be up to 5,000 hours. The total
service timer is adjustable between 0.0 and 50.0, in 0.5 increments, with 25.0
being equivalent to 2,500 hours (25.0 × 100).
Setting the parameter to 0 means that the timer will never expirei.e.,
there will be no overall maintenance reminder.
SRVC TRAC HRS
The traction service hours parameter is used to set the timer for the next
scheduled traction motor maintenance. The service interval can be up to 5,000
hours. The traction service timer is adjustable between 0.0 and 50.0, in 0.5
increments, with 25.0 being equivalent to 2,500 hours (25.0 × 100).
Setting the parameter to 0 means that the timer will never expirei.e.,
there will be no motor maintenance reminder.
DIS TOTL HRS
The total disable hours parameter is used to set the total disable timer; it can
be adjusted between 0 and 250 hours, in 1 hour increments. If the total disable
timer expires, the traction fault speed goes into effect.
Setting the parameter to 0 means that the total disable timer will never
expire and therefore never invoke the traction fault speed.
DIS TRAC HRS
The traction disable hours parameter is used to set the traction disable timer;
it can be adjusted between 0 and 250 hours, in 1 hour increments. If the traction
disable timer expires, the traction fault speed goes into effect.
Hourmeter Service Timer Setting
Hourmeter Disable Timer Setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis Instruments MultiMode 1243 Generation 2 and is the answer not in the manual?

Curtis Instruments MultiMode 1243 Generation 2 Specifications

General IconGeneral
BrandCurtis Instruments
ModelMultiMode 1243 Generation 2
CategoryController
LanguageEnglish

Related product manuals