Curtis 1243GEN2 Manual
48
3 — PROGRAMMABLE PARAMETERS:
Hourmeters
HOURMETER TYPE
The Spyglass gauge displays hourmeter data for 5 seconds each time the
keyswitch is turned on. The hourmeter type parameter denes whether the
total hourmeter or traction hourmeter data will be displayed. When this
parameter is programmed On, the total hourmeter is displayed; when pro-
grammed Off, the traction hourmeter is displayed.
PUMP METER
The pump meter parameter, when programmed On, congures the Fault
Output 1 line (at Pin 2) to function as an input to measure the hours a pump
is running. The pump is considered to be running when Pin 2 is at the battery
voltage. When the pump meter parameter is programmed On, the traction
hourmeter serves as a combination traction/pump hourmeter, and all the above
TRAC hourmeter parameters apply to both traction hours and pump hours.
The traction/pump hourmeter counts the hours when a direction is selected and
the hours when the pump is running.
Other Hourmeter Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis Instruments MultiMode 1243 Generation 2 and is the answer not in the manual?

Curtis Instruments MultiMode 1243 Generation 2 Specifications

General IconGeneral
BrandCurtis Instruments
ModelMultiMode 1243 Generation 2
CategoryController
LanguageEnglish

Related product manuals