5 — VEHICLE PERFORMANCE ADJUSTMENT
3
Setting the Vehicle’s Unloaded Top Speed
The controller and vehicle should be congured as follows prior to setting the
maximum unloaded vehicle speed:
Max Speed = 100%, all modes
Drive Current Limit as established in tuning procedure
2
Field Map = 50%
Field Map Start = 50% of the specied drive current limit
Field Min = manufacturers specied minimum (if available);
otherwise, 3 amps
Load Comp = 0
The vehicle should be unloaded
The vehicle battery should be fully charged.
The vehicle should be driven on a flat surface in a clear area during this
procedure. Since the vehicle may initially be traveling at speeds in excess of the
nal intended speed, precautions should be taken to ensure safety of test
personnel and anyone in the test area.
STEP 1. Select the programmers Program Menu and scroll down until the
Field Min parameter is at the top of the display.
STEP 2. Power up the vehicle and apply full throttle. While driving the
vehicle with full throttle applied, adjust the Field Min parameter
value to set the desired top speed. Increasing the Field Min value
decreases the vehicles top speed; decreasing the Field Min value
increases the vehicles top speed.
CAUTION:
Do not decrease the
Field Min parameter value below the motor manufacturers
recommended minimum eld current value, and do not increase
it above 10 amps.
STEP 3. If the Field Min parameter value is increased to 10 amps and the
vehicles top speed has still not been sufciently reduced, the Max
Speed parameter should be used to bring the vehicle top speed
down to the desired level. First, decrease the Field Min parameter
value, setting it to optimize smooth starting. Then adjust the
Max Speed parameter per Step 4 to bring the vehicle top speed
down to the desired level.
NOTE: If the Field Min parameter is set
too high, the high initial torque created by the high eld current
may cause overly abrupt starts; this is why we recommend using
the Max Speed parameter in those cases where a moderate Field
Min setting does not sufciently reduce the vehicle top speed.
STEP 4. Scroll up the Program Menu until the Max Speed parameter is at
the top of the display. While driving the vehicle with the Field
Min set at the value selected in Step 3, decrease the Max Speed
parameter value until the desired vehicle top speed is set.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis Instruments MultiMode 1243 Generation 2 and is the answer not in the manual?

Curtis Instruments MultiMode 1243 Generation 2 Specifications

General IconGeneral
BrandCurtis Instruments
ModelMultiMode 1243 Generation 2
CategoryController
LanguageEnglish

Related product manuals