Mar 2017 Page 61
© Penny & Giles Aerospace Ltd. No part of this work may be reproduced or distributed by any
means without prior permission in writing from the copyright owner.
DATA ACQUISITION FLIGHT RECORDER Type D51615-202-XXX or D51615-
202-XXX-090- with CCU Type D51616-XXXX and CAM Type D51623-XXXX
Installation and Operating Manual with Illustrated Parts
List
Commercial in Confidence
PIM434-I
(4) PRE Type D51620 Comprising;
(a) Professional Ground station (PGS).
(b) Ground Replay Cable SA109680.
(5) 28VDC 4 Amp Regulated Power Supply.
6.7.2 Procedure Using Internet Explorer
CVR Download
(1) Connect the Ground replay Cable SA109680 to the
DAFR main connector.
(2) Connect the Power Input plugs to the 28V power supply
(white wire to positive, black wire to negative).
Note: The recorder draws up to 4A on initial switch-on.
To avoid any possible damage to the unit, please ensure
that any power supply current limiting is disabled before
applying power.
(3) Apply power to the DAFR and the PC.
(4) Replay is started by either selecting the Internet
Explorer icon on the desktop or by selecting the
Internet Explorer task bar from the Task menu.
(5) Enter the recorder IP address of 10.0.0.100 in the
address box, and click ‘go’.
(6) Internet Explorer attempts to connect to the recorder. If
successful, the Recorder ‘Home’ page is displayed.
(7) With communications established, the home page on
which the navigation menu is displayed on the left of
the screen.
(8) Select the ‘File Download’ option and from the ‘File
Download’ page select the ‘Channel 1’ option.
Download the entire memory content as the length of
recording since the previous download cannot be
guaranteed. Save the file to an appropriate directory on
the host PC.
(9) Repeat for the remaining Channels 2, 3 and 4.
(10) On completion of the download, click the ‘OK’ button in
the download complete message box, return to the
Home page by selecting ‘Home’ on the Navigation
menu. Select ‘File, Close’ or click on the window close
box to the top right of the window.