Curtiss-Wright | Tritex II AC 90, 115 Rev. X PN39892 7/12/22
24
Specifications: Size 115 Linear Actuators
T2M/X115
Stator
1 Stack
2 Stack
3 Stack
Lead
RPM @ 240 VAC
3000
2000
1500
0.1
Continuous Force
lbf (N)
2,060 (9,163)
3,224 (14,341)
NA
Peak Force
lbf (N)
4,120 (18,327)
5,400 (24,020)
NA
Max Speed
in/sec (mm/sec)
5.00 (127)
3.33 (84)
NA
T2X - C
a
(Dynamic Load Rating)
lbf (N)
7900 (35141)
NA
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4736 (21067)
NA
0.2
Continuous Force
lbf (N)
1,177 (5,235)
1,843 (8,198)
2,380 (10,586)
Peak Force
lbf (N)
2,354 (10,471)
3,685 (16,392)
4,760 (21,174)
Max Speed
in/sec (mm/sec)
10.00 (254)
6.67 (169)
5.00 (127)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
8300 (36920)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4890 (21751)
0.5
Continuous Force
lbf (N)
530 (2,358)
829 (3,688)
1,071 (4,764)
Peak Force
lbf (N)
1,059 (4711)
1,658 (7,375)
2,142 (9,528)
Max Speed
in/sec (mm/sec)
25.00 (635)
16.67 (423)
12.50 (317)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
7030 (31271)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
4218 (18763)
0.75
Continuous Force
lbf (N)
353 (1,570)
553 (2,460)
714 (3,176)
Peak Force
lbf (N)
706 (3,140)
1,106 (4,920)
1,428 (6,352)
Max Speed
in/sec (mm/sec)
37.5 (953)
25 (635)
17.75 (450)
T2X - C
a
(Dynamic Load Rating)
lbf (N)
6335 (28179)
T2M - C
a
(Dynamic Load Rating)
lbf (N)
3328 (14804)
Drive Current @ Continuous Force
Amps
8.5
8.5
8.5
Available Stroke Lengths
in (mm)
4 (102), 6 (150), 10 (254), 12 (300), 18 (450)
Inertia (zero stroke)
lb-in-s
2
/ Kg-m
2
0.01132
(0.000012790)
0.01232
(0.00001392)
0.01332
(0.00001505)
Inertia Adder (per inch of stroke)
lb-in-s
2
/in/ Kg-m
2
/in
0.0005640 (0.0000006372)
Approximate Weight
lb (kg)
34 (15.5) for 6 inch stroke, 1 stack. Add 2 (1) per inch of stroke. Add
8 (4) per motor stack. Add 4 (2) for brake.
Operating Temperature Range
*
-20 to 65˚ C (-40˚C available, consult Exlar)
Continuous AC Input Current
**
Amps
8.3
8.3
8.3
*Ratings based on 25˚C conditions. ** Continuous input current rating is defined by UL and CSA.