CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E 158
GPO_DATA
0xda
1.5.120 GPO_DATA
Address = 0xda
GPO state values that the device is outputting. If GPOs are outputting PWM, these bits reflect the duty cycle selection (LOW
or HIGH). Bits corresponding to disabled GPO are 0. This register is not applicable for part CY8CMBR3106S.
Address: 0xda
Bits 76543210
Host AccessRRRRRRRR
Device Access RW RW RW RW RW RW RW RW
Bit Name GPO7 GPO6 GPO5 GPO4 GPO3 GPO2 GPO1 GPO0
Bits Name Description
7 GPO7 GPO7 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
6 GPO6 GPO6 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
5 GPO5 GPO5 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108, CY8CMBR3110.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
4 GPO4 GPO4 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S,
CY8CMBR3108.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
3 GPO3 GPO3 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
2 GPO2 GPO2 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
1 GPO1 GPO1 value indicator. This bit field is not applicable for parts CY8CMBR3102, CY8CMBR3106S.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle
0 GPO0 GPO0 value indicator. This bit field is not applicable for part CY8CMBR3106S.
0: Low DC output/PWM duty cycle
1: High DC output/PWM duty cycle