CapSense Express Controllers Registers TRM, Document No. 001-91082 Rev. *E 123
SNS_VDD_SHORT
0x9a
1.5.91 SNS_VDD_SHORT
Address = 0x9a
Indicators of sensors with short circuit to Vdd. If System diagnostics feature is disabled (DEVICE_CFG1.SYSD_EN = 0), this
register's content is invalid.
Address: 0x9a
Bits 15 14 13 12 11 10 9 8
Host AccessRRRRRRRR
Device Access RW RW RW RW RW RW RW RW
Bit Name CS15 CS14 CS13 CS12 CS11 CS10 CS9 CS8
Bits 76543210
Host AccessRRRRRRRR
Device Access RW RW RW RW RW RW RW RW
Bit Name CS7 CS6 CS5 CS4 CS3 CS2 CS1 CS0
Bits Name Description
15 CS15 Sensor 15 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
14 CS14 Sensor 14 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
13 CS13 Sensor 13 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
12 CS12 Sensor 12 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
11 CS11 Sensor 11 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
10 CS10 Sensor 10 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108, CY8CMBR3110.
0: No short circuit to Vdd or sensor not tested
1: Short circuit to Vdd detected
9 CS9 Sensor 9 short to Vdd indicator. This bit field is not applicable for parts CY8CMBR3102,
CY8CMBR3108.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cypress CapSense Express CY8CMBR3108 and is the answer not in the manual?

Cypress CapSense Express CY8CMBR3108 Specifications

General IconGeneral
BrandCypress
ModelCapSense Express CY8CMBR3108
CategoryController
LanguageEnglish

Related product manuals