DGS-3630 Series Layer 3 Stackable Managed Switch Hardware Installation Guide
61
Redundant Power Supply (RPS) Cable
When connecting the Switch to a Redundant Power Supply, an RPS cable is necessary. Please review these products
for matching cable pin assignment. The following diagrams and tables show the standard RPS receptacle/connector
and their pin assignments.
14-pin DC power cable
Figure Error! Use the Home tab to apply AppendixHeading to the text that you want to appear here.-1 Redundant Power Supply
(RPS) 14-pin DC Power Cable
RPS 14-pin DC Power Cable Pin Assignments
Pin
Device
DPS-500
1
NC
NC
2
GND
GND
3
GND
GND
4
GND
GND
5
GND
GND
6
+12V
+12V
7
+12V
+12V
8
RS+
RS+
9
NC
GND
10
NC
Power Good
11
GND
NC
12
Power Good
NC
13
+5V
+5V
14
+12V
+12V
RPS 14-pin DC Power Cable Pin Assignments