SQLC-214-097
13
(5) Current input 3φ3W (2CT) (6) Current input 3φ3W (3CT)
14
( )
13
( )
EXT.INPUT1
EXT.INPUT2
EXT.INPUT1
EXT.INPUT2
14
( )
13
( )
( )
AUX.SUPPLY
LOAD
2
7
5
6
1
V
CT
U W
ANALOG OUTPUT3
CONTACT OUTPUT2
CONTACT OUTPUT1
ANALOG OUTPUT4
ANALOG OUTPUT2
ANALOG OUTPUT1
20
14
26
15
28
29
27
13
12
25
24
23
22
21
18
19
17
16
15
ANALOG OUTPUT3
CONTACT OUTPUT2
CONTACT OUTPUT1
ANALOG OUTPUT4
ANALOG OUTPUT2
ANALOG OUTPUT1
AUX.SUPPLY
LOAD
( )
13
W
CT
UV
2
20
7
5
6
3
4
14
26
15
28
29
27
13
12
25
24
23
22
21
1
18
19
17
16
( )
15
( )
13
(7) Current input 1φ3W (8) Current input 1φ2W
( )
( )
13
( )
14
EXT.INPUT2
EXT.INPUT1
CT
AUX.SUPPLY
LOAD
1
6
7
2
5
U W
ANALOG OUTPUT1
ANALOG OUTPUT2
ANALOG OUTPUT4
CONTACT OUTPUT1
CONTACT OUTPUT2
ANALOG OUTPUT3
18
25
13
14
15
26
27
29
28
12
20
21
22
23
24
19
16
17
15
ANALOG OUTPUT1
ANALOG OUTPUT2
ANALOG OUTPUT4
CONTACT OUTPUT1
CONTACT OUTPUT2
ANALOG OUTPUT3
EXT.INPUT2
EXT.INPUT1
( )
13
( )
14
AUX.SUPPLY
CT
LOAD
( )
13
VU
1
18
6
7
2
5
25
13
14
15
26
27
29
28
12
20
21
22
23
24
19
16
17
( )
15
( )
13
(9) Voltage input 3φ3W (10) Voltage input 1φ3W
LOAD
10
9
8
UVW
VT
LOAD
NUW
10
9
8
AUX.SUPPLY
1
2
5
6
7
( )
13
( )
14
EXT.INPUT2
EXT.INPUT1
( )
ANALOG OUTPUT1
ANALOG OUTPUT2
ANALOG OUTPUT4
CONTACT OUTPUT1
CONTACT OUTPUT2
ANALOG OUTPUT3
15
( )
13
20
26
27
29
28
21
22
23
24
25
16
17
19
18
AUX.SUPPLY
1
2
5
6
7
( )
13
( )
14
EXT.INPUT2
EXT.INPUT1
( )
ANALOG OUTPUT1
ANALOG OUTPUT2
ANALOG OUTPUT4
CONTACT OUTPUT1
CONTACT OUTPUT2
ANALOG OUTPUT3
15
( )
13
20
26
27
29
28
21
22
23
24
25
16
17
19
18
(11) Voltage input 1φ2W
( )
( )
13
( )
14
28
EXT.INPUT2
EXT.INPUT1
29
UV
AUX.SUPPLY
LOAD
VT
5
6
7
1
2
ANALOG OUTPUT1
ANALOG OUTPUT2
ANALOG OUTPUT4
CONTACT OUTPUT1
CONTACT OUTPUT2
ANALOG OUTPUT3
22
26
27
23
24
25
9
8
20
21
16
17
19
18
15
( )
13
Note(
13
) Analog output, contact output, external operation
input is an option.
Note(
14
) Can change to external reset function or
external display change function by setting.
Note(
15
) Can choose the contact output among the pulse output,
the alarm output, the CPU error
output. (Designation)
・Combination of contact output
Contact output 1 Contact output 2
Pulse+Alarm Pulse output Alarm output
Alarm×2 Alarm output 1 Alarm output 2
Pulse×2 Pulse output 1 Pulse output 2
Pulse+CPU error Pulse output CPU error output
Alarm+CPU error Alarm output CPU error output
Note(
16
) In case of low-voltage circuit, secondary side
grounding of VT and CT is unnecessary. And, VT is
unnecessary in case it used 110V or direct 220V.

Related product manuals