10 | Configuration
Installer reference guide
168
ERGA04~08EAV3(A) + EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
▪ You have programmed a quiet mode schedule:
- During the night: Most quiet.
- During the day: Off to ensure the heating/cooling capacity of the system.
▪ However, during the afternoon the baby is sleeping and you want it to be quiet.
Then you can do the following:
1 Go to [7.4.1]: User settings > Quiet > Activation.
2 Select Most quiet.
Advantage:
The outdoor unit runs in its most quiet level.
Electricity prices and gas price
Only applicable in combination with the bivalent function. See also
"Bivalent"[4183].
# Code Description
[7.5.1] N/A Electricity price > High
[7.5.2] N/A Electricity price > Medium
[7.5.3] N/A Electricity price > Low
[7.6] N/A Gas price
INFORMATION
Electricity price can only be set when bivalent is ON ([9.C.1] or [C-02]). These values
can only be set in menu structure [7.5.1], [7.5.2] and [7.5.3]. Do NOT use overview
settings.
To set the gas price
1 Go to [7.6]: User settings > Gas price.
2 Select the correct gas price.
3 Confirm the changes.
INFORMATION
Price value ranging from 0.00~990valuta/kWh (with 2 significant values).
To set the electricity price
1 Go to [7.5.1]/[7.5.2]/[7.5.3]: User settings > Electricity
price > High/Medium/Low.
2 Select the correct electricity price.
3 Confirm the changes.
4 Repeat this for all three electricity prices. —
INFORMATION
Price value ranging from 0.00~990valuta/kWh (with 2 significant values).