10 | Configuration
Installer reference guide
148
ERGA04~08EAV3(A) + EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
# Code Description
[2.E] N/A 2-points
Slope-Offset
10.5.4 Additional zone
Overview
The following items are listed in the submenu:
3
Additional zone
Space heating/cooling
Main zone
Room
Tank
[3] Additional zone
Setpoint screen
[3.1] Schedule
[3.2] Heating schedule
[3.3] Cooling schedule
[3.4] Setpoint mode
[3.5] Heating WD curve
[3.6] Cooling WD curve
[3.7] Emitter type
[3.8] Setpoint range
[3.9] Control
[3.A] Thermostat type
[3.B] Delta T
[3.C] WD curve type
Setpoint screen
Control the leaving water temperature for the additional zone via setpoint screen
[3] Additional zone.
See "10.3.5Setpoint screen"[4124].
Schedule
Indicates if the desired leaving water temperature is according to a schedule.
See "10.5.3Main zone"[4139].
# Code Description
[3.1] N/A Schedule:
No
Yes
Heating schedule
Define a heating temperature schedule for the additional zone via [3.2] Heating
schedule.
See "10.3.7Schedule screen: Example"[4126].
Setpoint mode
The setpoint mode of the additional zone can be independently set from the
setpoint mode of the main zone, see "Setpoint mode"[4140].