EasyManua.ls Logo

Daikin Altherma 3 R F EHVZ04S18E 6V Series - Setting up the Power Consumption Control; Permanent Power Limitation

Daikin Altherma 3 R F EHVZ04S18E 6V Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Application guidelines
Installer reference guide
39
ERGA04~08EAV3(A) + EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
a Electrical cabinet (L
1
/N): Preferential kWh rate power supply
b Electrical cabinet (L
1
/L
2
/L
3
/N): Normal kWh rate power supply
c Power meter (L
1
/N)
d Power meter (L
1
/L
2
/L
3
/N)
e Fuse (L
1
/N)
f Fuse (L
1
/L
2
/L
3
/N)
g Outdoor unit (L
1
/N)
h Indoor unit (L
1
/N)
i Backup heater (L
1
/L
2
/L
3
/N)
6.5 Setting up the power consumption control
The power consumption control:
- Allows you to limit the power consumption of the entire system (sum of
outdoor unit, indoor unit and backup heater).
- Configuration: Set the power limitation level and how it has to be achieved via
the user interface.
The power limitation level can be expressed as:
- Maximum running current (inA)
- Maximum power input (inkW)
The power limitation level can be activated:
- Permanently
- By digital inputs
NOTICE
Set a minimum power consumption of ±3.6kW to guarantee:
Defrost operation. Otherwise, if defrosting is interrupted several times, the heat
exchanger will freeze up.
Space heating and DHW production by allowing the backup heater step1.
6.5.1 Permanent power limitation
Permanent power limitation is useful to assure a maximum power or current input
of the system. In some countries, legislation limits the maximum power
consumption for space heating and DHW production.
P
i
t
DI
a
b
P
i
Power input
t Time
DI Digital input (power limitation level)
a Power limitation active
b Actual power input
Setup and configuration
No additional equipment needed.

Table of Contents