EasyManua.ls Logo

Daikin Altherma 3 R F EHVZ04S18E 6V Series - To Clean the Water Filter in Case of Trouble

Daikin Altherma 3 R F EHVZ04S18E 6V Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 | Maintenance and service
Installer reference guide
209
ERGA04~08EAV3(A) + EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
a
b
a
a Clip
b Magnetic filter/dirt separator
8 Remove the water filter.
9 Remove the drain hose from the water filter.
CAUTION
Although the water circuit is drained, some water may be spilled when removing the
magnetic filter/dirt separator from the filter housing. ALWAYS clean up spilled water.
13.5.2 To clean the water filter in case of trouble
1 Remove the water filter from the unit. See "13.5.1 To remove the water
filter"[4208].
CAUTION
To protect the piping connected to the magnetic filter/dirt separator from damage it
is recommended to perform this procedure with the magnetic filter/dirt separator
removed from the unit.
2 Unscrew the bottom of the water filter housing. Use an appropriate tool if
needed.
CAUTION
Opening the magnetic filter/dirt separator is ONLY required in case of severe issues.
Preferably this action is never to be done during the complete lifetime of the
magnetic filter/dirt separator.
a
b
a Bottom part to be unscrewed
b Water filter housing
3 Remove the strainer and the rolled‑up filter from the water filter housing and
clean with water.
4 Install the cleaned rolled‑up filter and strainer in the water filter housing.

Table of Contents

Related product manuals