14 | Troubleshooting
Installer reference guide
211
ERGA04~08EAV3(A) + EHVZ04+08S18+23EA6V+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
14 Troubleshooting
Contact
For the symptoms listed below, you can try to solve the problem yourself. For any
other problem, contact your installer. You can find the contact/helpdesk number
via the user interface.
1 Go to [8.3]: Information > Dealer information.
In this chapter
14.1 Overview: Troubleshooting .................................................................................................................................................... 211
14.2 Precautions when troubleshooting........................................................................................................................................ 211
14.3 Solving problems based on symptoms................................................................................................................................... 212
14.3.1 Symptom: The unit is NOT heating or cooling as expected .................................................................................. 212
14.3.2 Symptom: Hot water does NOT reach the desired temperature ......................................................................... 213
14.3.3 Symptom: The compressor does NOT start (space heating or domestic water heating) .................................... 213
14.3.4 Symptom: The system is making gurgling noises after commissioning................................................................ 213
14.3.5 Symptom: The pump is making noise (cavitation) ................................................................................................ 214
14.3.6 Symptom: The pressure relief valve opens ........................................................................................................... 214
14.3.7 Symptom: The water pressure relief valve leaks................................................................................................... 215
14.3.8 Symptom: The space is NOT sufficiently heated at low outdoor temperatures .................................................. 215
14.3.9 Symptom: The pressure at the tapping point is temporarily unusually high ....................................................... 216
14.3.10 Symptom: Decoration panels are pushed away due to a swollen tank................................................................ 216
14.3.11 Symptom: Tank disinfection function is NOT completed correctly (AH-error) .................................................... 216
14.4 Solving problems based on error codes................................................................................................................................. 217
14.4.1 To display the help text in case of a malfunction.................................................................................................. 217
14.4.2 Error codes: Overview............................................................................................................................................ 218
14.1 Overview: Troubleshooting
This chapter describes what you have to do in case of problems.
It contains information about:
Solving problems based on symptoms
Solving problems based on error codes
Before troubleshooting
Carry out a thorough visual inspection of the unit and look for obvious defects such
as loose connections or defective wiring.
14.2 Precautions when troubleshooting
WARNING
When carrying out an inspection on the switch box of the unit, ALWAYS make
sure that the unit is disconnected from the mains. Turn off the respective circuit
breaker.
When a safety device was activated, stop the unit and find out why the safety
device was activated before resetting it. NEVER shunt safety devices or change
their values to a value other than the factory default setting. If you are unable to
find the cause of the problem, call your dealer.
DANGER: RISK OF ELECTROCUTION