Error code Description
E5-00 OU: Overheat of inverter compressor motor
E6-00 OU: Compressor startup defect
E7-00 OU: Malfunction of outdoor unit fan motor
E8-00 OU: Power input overvoltage
E9-00 Malfunction of electronic expansion valve
EA-00 OU: Cool/heat switchover problem
EC-00 Abnormal increase tank temperature
EC-04 Tank preheating
F3-00 OU: Malfunction of discharge pipe temperature
F6-00 OU: Abnormal high pressure in cooling
FA-00 OU: Abnormal high pressure, actuation of HPS
H0-00 OU: Voltage/current sensor problem
H1-00 External temperature sensor problem
H3-00 OU: Malfunction of high pressure switch (HPS)
H5-00 Malfunction of compressor overload protection
H6-00 OU: Malfunction of position detection sensor
H8-00 OU: Malfunction of compressor input (CT)
system
H9-00 OU: Malfunction of outdoor air thermistor
HC-00 Tank temperature sensor problem
HC-01 Second tank temperature sensor problem
HJ-10 Water pressure sensor abnormality
J3-00 OU: Malfunction of discharge pipe thermistor
J6-00 OU: Malfunction of heat exchanger thermistor
J6-07 OU: Malfunction of heat exchanger thermistor
JA-00 OU: Malfunction of high pressure sensor
L1-00 Malfunction of INV PCB
L3-00 OU: Electrical box temperature rise problem
L4-00 OU: Malfunction of inverter radiating fin
temperature rise
L5-00 OU: Inverter instantaneous overcurrent (DC)
L8-00 Malfunction triggered by a thermal protection
in the inverter PCB
L9-00 Prevention of compressor lock