Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
4.5 [F-0D] R/W 0: Continuous
1: Sample
2: Request
4.6 [E-02] R/O
1: Heatin
g
onl
y
└─ Pump limitation
4.8.1 [9-0E] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
4.8.2 [9-0D] R/W 0~8, step:1
0 : No limitation
1~4 : 50~80%
5~8 : 50~80% during sampling
6
Space heating / cooling
4.9 [F-00] R/W
0: Restricted
1: Allowed
4.A [D-03] R/W 0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
4.B [9-04] R/W 1~4°C, step: 1°C
1°C
4.C [2-06] R/W 0: Disabled
1: Enabled
Tank
5.2 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
5.3 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
5.4 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
5.6 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
└─ Disinfection
5.7.1 [2-01] R/W 0: No
1: Yes
5.7.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
5.7.3 [2-02] R/W 0~23 hour, step: 1 hour
1
5.7.4 [2-03] R/W
60°C
5.7.5 [2-04] R/W 40~60 min, step: 5 min
40 min
Tank
5.8 [6-0E] R/W 40~60°C, step: 1°C
60°C
5.9 [6-00] R/W 2~40°C, step: 1°C
25°C
5.A [6-08] R/W
2~20°C, step: 1°C
10°C
5.B R/W
0: Fixed
1: Weather de
p
endent
└─ WD curve
5.C [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
5.C [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
5.C [0-0D] R/W 10~25°C, step: 1°C
15°C
5.C [0-0E] R/W -40~5°C, step: 1°C
-10°C
Tank
5.D [6-01] R/W 0~10°C, step: 1°C
2°C
User settings
└─ Quiet
7.4.1 R/W
0: OFF
1: Quiet
2: More quiet
3: Most quiet
4: Automatic
└─ Electricity price
7.5.1 R/W 0,00~990/kWh
1/kWh
7.5.2 R/W 0,00~990/kWh
1/kWh
7.5.3 R/W 0,00~990/kWh
1/kWh
User settings
7.6 R/W 0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Installer settings
└─ Configuration wizard
└─ System
9.1 [E-03] R/O
2: 3V (*1)
3: 6V (*2)
4: 9W
(
*3
)
9.1 [E-05]
[E-06]
[E-07]
R/O
3: Integrated
Operation day
Overshoot
Duration
Tank setpoint
Hysteresis
Hysteresis
Start time
Setpoint mode
Maximum
Heat up mode
Reheat setpoint
Eco setpoint
Comfort setpoint
Antifrost
Increase around 0°C
Additional zone
Main zone
Pump operation mode
Unit type
Pump outside range
Gas price
BUH type
Domestic hot water
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Margin
Activation
High
Medium
Low
Activation
(*1) *3V_
(*2) *6V_
(*3) *9W
(#) Setting is not applicable for this unit. 4P629095-1 - 2020.09