6/11
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
└─ Benefit kWh power supply
9.8.2 [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.8.3 [D-05] R/W 0: Forced off
1: As normal
9.8.4 [D-01] R/W
0: No
1: Active open
2: Active closed
3: Smart
rid
9.8.6 0: No
1: Yes
9.8.8 0~20 kW, step: 0,5 kW
20 kW
└─ Power consumption control
9.9.1 [4-08] R/W
0: No limitation
1: Continuous
2: Di
uts
9.9.2 [4-09] R/W 0: Current
1: Power
9.9.3 [5-05] R/W 0~50 A, step: 1 A
50
9.9.4 [5-05] R/W 0~50 A, step: 1 A
50
9.9.5 [5-06] R/W 0~50 A, step: 1 A
50
9.9.6 [5-07] R/W 0~50 A, step: 1 A
50
9.9.7 [5-08] R/W 0~50 A, step: 1 A
50
9.9.8 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.9 [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.A [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.B [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.C [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
9.9.D [4-01]
0: None
1: BSH
2: BUH
└─ Energy metering
9.A.1 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
ulse/kWh
9.A.2 [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
ulse/kWh
└─ Sensors
9.B.1 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
9.B.2 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
9.B.3 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Bivalent
9.C.1 [C-02] R/W
0: No
1: Bivalent
9.C.2 [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
low
9.C.3 [C-03] R/W -25~25°C, step: 1°C
0°C
9.C.4 [C-04] R/W 2~10°C, step 1°C
3°C
Installer settings
9.D [C-09] R/W
0: Normally open
1: Normall
closed
9.E [3-00] R/W 0: No
1: Yes
9.F [E-08] R/W 0: Disabled
1: Enabled
9.G R/W 0: No
1: Yes
└─ Overview field settings
9.I [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
9.I [0-01] R/W [9-05]~[9-06]°C, step: 1°C
50°C
9.I [0-02] R/W 10~25°C, step: 1°C
15°C
9.I [0-03] R/W -40~5°C, step: 1°C
-10°C
9.I [0-04] R/W [9-07]~[9-08]°C, step: 1°C
8°C
9.I [0-05] R/W [9-07]~[9-08]°C, step: 1°C
12°C
Allow heater
Allow pump
Benefit kWh power supply
Allow electric heaters
Limit setting kW
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
Auto restart
Power saving function
Disable protections
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Temperature
Hysteresis
Alarm output
Priority heater
Electricity meter 1
Electricity meter 2
External sensor
Ext. amb. sensor offset
Averaging time
Bivalent
Boiler efficiency
Limit 4
Limit
Limit 1
Limit 2
Limit 3
Limit 4
Power consumption control
Type
Limit
Limit 1
Limit 2
Limit 3
4P629091-1C - 2022.08
(*1) *3V*_(*2) *6V*_(*3) *9W*_
(*4) EHB*_(*5) EHV*_
(*6) *X*_(*7) *H*