7/11
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.I [0-06] R/W 25~43°C, step: 1°C
35°C
9.I [0-07] R/W 10~25°C, step: 1°C
20°C
9.I [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
9.I [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
9.I [0-0D] R/W 10~25°C, step: 1°C
15°C
9.I [0-0E] R/W -40~5°C, step: 1°C
-10°C
9.I [1-00] R/W -40~5°C, step: 1°C
-10°C
9.I [1-01] R/W 10~25°C, step: 1°C
15°C
9.I [1-02] R/W
[9-01]~[9-00], step: 1°C
35°C
9.I [1-03] R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
9.I [1-04] R/W 0: Disabled
1: Enabled
9.I [1-05] R/W 0: Disabled
1: Enabled
9.I [1-06] R/W 10~25°C, step: 1°C
20°C
9.I [1-07] R/W
25~43°C, step: 1°C
35°C
9.I [1-08] R/W [9-03]~[9-02]°C, step: 1°C
22°C
9.I [1-09] R/W [9-03]~[9-02]°C, step: 1°C
18°C
9.I [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
9.I [1-0B] R/W 3~10°C, step: 1°C
5°C
9.I [1-0C] R/W 3~10°C, step: 1°C
5°C
9.I [1-0D] R/W 3~10°C, step: 1°C
5°C
9.I [1-0E] R/W 3~10°C, step: 1°C
5°C
9.I [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
9.I [2-01] R/W 0: No
1: Yes
9.I [2-02] R/W 0~23 hour, step: 1 hour
1
9.I [2-03] R/W [E-07]≠
1 :
55~75°C, step: 5°C
70°C
[E-07]=1 : 60°C
60°C
9.I [2-04] R/W [E-07]≠1: 5~60 min, step: 5 min
10 min
[E-07]=1: 40~60 min, step: 5 min
40 min
9.I [2-05] R/W 4~16°C, step: 1°C
12°C
9.I [2-06] R/W 0: Disabled
1: Enabled
9.I [2-09] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0A] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0B] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0C] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I [2-0D] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I [2-0E] R/W 0~50 A, step: 1 A
50
9.I [3-00] R/W 0: No
1: Yes
9.I [3-01]
0
9.I [3-02]
1
9.I [3-03]
4
9.I [3-04]
2
9.I [3-05]
1
9.I [3-06] R/W 18~30°C, step: 1°C
30°C
9.I [3-07] R/W 12~18°C, step: 1°C
12°C
9.I [3-08] R/W 25~35°C, step: 1°C
35°C
9.I [3-09] R/W 15~25°C, step: 1°C
15°C
9.I [4-00] R/W 0: Disabled
1: Enabled
2: Onl
DHW
What is the minimum desired room temperature in cooling?
How long must the tank temperature be maintained?
Room antifrost temperature
Room frost protection
Adjust the offset on the measured room temperature
What is the required offset on the measured outdoor temp.?
--
Is auto restart of the unit allowed?
--
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
What is the disinfection target temperature?
What emitter type is connected to the main LWT zone?
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Adjust the offset on the measured room temperature
Should the disinfection function be executed?
When should the disinfection function start?
What is the mimimum desired room temperature in heating?
What is the maximum desired room temperature in cooling?
What is the BUH operation mode?
--
What is the maximum desired room temperature in heating?
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
When should the disinfection function be executed?
Low ambient temp. for LWT main zone cooling WD curve.
--
--
What emitter type is connected to the additional LWT zone?
What is the maximum allowed current over the heatpump ?
What is the desired delta T in cooling for the main zone?
What is the desired delta T in cooling for the additional zone?
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
What is the desired delta T in heating for the main zone?
Weather dependent cooling of the main leaving water temperature zone.
Weather dependent cooling of the additional leaving water temperature zone
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
What is the averaging time for the outdoor temp?
What is the desired delta T in heating for the additional zone?
(*1) *3V*_(*2) *6V*_(*3) *9W*_
(*4) EHB*_(*5) EHV*_
(*6) *X*_(*7) *H*
4P629091-1C - 2022.08