10/11
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.I [C-0A]
0
9.I [C-0B]
0
9.I [C-0C]
0
9.I [C-0D]
0
9.I [C-0E]
0
9.I [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I [D-01] R/W
0: No
1: Active open
2: Active closed
3: Smart
g
rid
9.I [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
9.I [D-03] R/W 0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, s
p
an 8°C
9.I [D-04] R/W
0: No
1: Pwr consm
p
ctrl
9.I [D-05] R/W 0: Forced off
1: As normal
9.I [D-07] R/W
0: No
1: Yes
9.I [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
9.I [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100
p
ulses/m³
(g
as meter
)
9.I [D-0A]
0
9.I [D-0B]
2
9.I [D-0C]
0
9.I [D-0D]
0
9.I [D-0E]
0
9.I [E-00] R/O
0~5
0: LT s
p
lit
9.I [E-01] R/O
0
9.I [E-02] R/W (*6)
R/O (*7)
0: Reversible (*6)
1: Heating only (*7)
9.I [E-03] R/O
2: 3V (*1)
3: 6V (*2)
4: 9W
(
*3
)
9.I [E-04] R/O 0: No
1: Yes
9.I [E-05] R/W
0: No (*4)
1: Yes
(
*5
)
9.I [E-06] R/O 0: No
1: Yes
9.I [E-07] R/W
0~6
0: EKHW (*4)
1: Integrated (*5)
5: EKHWP
(
*4
)
9.I [E-08] R/W 0: Disabled
1: Enabled
9.I [E-09]
1
9.I [E-0A]
0
9.I [E-0B]
0
9.I [E-0C]
0
9.I [E-0D]
0
9.I [E-0E]
0
9.I [F-00] R/W
0: Disabled
1: Enabled
9.I [F-01] R/W 10~35°C, step: 1°C
20°C
9.I [F-02] R/W 3~10°C, step: 1°C
3°C
9.I [F-03] R/W 2~5°C, step: 1°C
5°C
9.I [F-04] R/W
0: No
1: Yes
9.I [F-05]
0
9.I [F-09] R/W
0: Disabled
1: Enabled
9.I [F-0A]
0
9.I [F-0B] R/W
0: No
1: Yes
9.I [F-0C] R/W 0: No
1: Yes
9.I [F-0D] R/W 0: Continuous
1: Sample
2: Re
q
uest
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
--
Close shut-off valve during cooling?
What is the pump operation mode?
Bottom plate heater hysteresis.
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
Close shut-off valve during thermo OFF?
--
--
Pump operation during flow abnormality.
--
Is a bi-zone kit installed?
--
Above which outdoor temperature is cooling allowed?
Bottom plate heater ON temperature.
Pump operation allowed outside range.
Is glycol present in the system?
--
--
Is a bottom plate heater connected?
--
Contact type of preferential kWh rate PS installation?
--
--
--
What is the indoor unit software type?
What is the number of backup heater steps?
Is the power saving function available on the outdoor unit?
Which type of unit is installed?
Which type of compressor is installed?
Is a demand PCB connected?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement?
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
--
--
4P629091-1C - 2022.08
(*1) *3V*_(*2) *6V*_(*3) *9W*_
(*4) EHB*_(*5) EHV*_
(*6) *X*_(*7) *H*