Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.I [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
9.I [7-03]
2.5
9.I [7-04]
0
9.I [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
low
9.I [7-06] R/W
0: Disabled
1: Enabled
9.I [7-07] R/W
0: Disabled
1: Enabled
9.I [8-00] R/W
0~20 min, step 1 min
1 min
9.I [8-01] R/W 5~95 min, step: 5 min
30 min
9.I [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour
≠1
9.I [8-03] R/W 20~95 min, step: 5 min
50 min
9.I [8-04] R/W 0~95 min, step: 5 min
95 min
9.I [8-05] R/W
0: No
1: Yes
9.I [8-06] R/W 0~10°C, step: 1°C
5°C
9.I [8-07] R/W [9-03]~[9-02], step: 1°C
18°C
9.I [8-08] R/W [9-03]~[9-02], step: 1°C
20°C
9.I [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
9.I [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
9.I [8-0B]
13
9.I [8-0C]
10
9.I [8-0D]
16
9.I [9-00] R/W [2-0C]=2:
37~65, step: 1°C
55°C
[2-0C]≠2:
37~55, step: 1°C
55°C
9.I [9-01] R/W 15~37°C, step: 1°C
25°C
9.I [9-02] R/W 18~22°C, step: 1°C
22°C
9.I [9-03] R/W 5~18°C, step: 1°C
5°C
9.I [9-04] R/W 1~4°C, step: 1°C
1°C
9.I [9-05] R/W 15~37°C, step: 1°C
25°C
9.I [9-06] R/W [2-0D]=2:
37~65, step: 1°C
55°C
[2-0D]≠2:
37~55, step: 1°C
55°C
9.I [9-07] R/W 5~18°C, step: 1°C
5°C
9.I [9-08] R/W 18~22°C, step: 1°C
22°C
9.I [9-09] R/W 1~18°C, step: 1°C
18°C
9.I [9-0A] R/W [3-07]~[3-06]°C, step: 0,5°C
23°C
9.I [9-0B] R/W [3-09]~[3-08]°C, step: 0,5°C
23°C
9.I [9-0C] R/W 1~6°C, step: 0,5°C
1 °C
9.I [9-0D] R/W 0~8, step:1
0: No limitation
1~4: 90~60% pump speed
5~8: 90~60% pump speed during
sampling
6
9.I [9-0E]
6
9.I [C-00] R/W
0: Solar priority
1: Heat
9.I [C-01]
0
9.I [C-02] R/W
0: No
1: Bivalent
9.I [C-03] R/W -25~25°C, step: 1°C
0°C
9.I [C-04] R/W 2~10°C, step 1°C
3°C
9.I [C-05] R/W 0: -
1: 1 contact
2: 2 contacts
9.I [C-06] R/W 0: -
1: 1 contact
2: 2 contacts
9.I [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
9.I [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
9.I [C-09] R/W
0: Normally open
1: Normall
closed
Heating comfort setpoint
Cooling comfort setpoint
Which type of external sensor is installed?
Is an external backup heat source connected?
Bivalent activation temperature.
Bivalent hysteresis temperature.
What is the allowed undershoot in cooling?
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Pump speed limitation
--
Domestic heating water priority.
What is the required alarm output contact type?
--
What is the mimimum desired LWT for main zone in cooling?
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
What is the mimimum desired LWT for add. zone in cooling?
What is the maximum desired LWT for add. zone in cooling?
Room temperature hysteresis.
--
--
--
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
What is the maximum desired LWT for main zone in cooling?
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
What is the desired comfort main LWT in cooling?
What is the desired eco main LWT in cooling?
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
Maximum running time for domestic hot water operation.
Anti-recycling time.
Compressor forced off
BBR16 activation
Booster heater delay timer.
Additional running time for the maximum running time.
How many leaving water temperature zones are there?
--
--
Boiler efficiency
Minimum running time for domestic hot water operation.
(*1) *3V*_(*2) *6V*_(*3) *9W*_
(*4) EHB*_(*5) EHV*_
(*6) *X*_(*7) *H*
4P629091-1C - 2022.08