Daikin Enfinity VFC - Unit Check; Equipment Data; Recording Equipment Performance Measurements

Daikin Enfinity VFC
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IM 930-6 EnnityVerticalWaterSourceHeatPumps 40 www.DaikinApplied.com
Unit Check / Equipment Data
Installation Data
Job Name ___________________________________________________ CheckTestDate:__________________________
City__________________________________________________________ State _______________ Zip______________
Daikin Model # ______________________________________________________
Daikin Serial # _______________________________________ JobsiteUnitID#(HP#)_____________________________
General Contractor:_____________________________________ MechanicalContractor:_____________________________
Technician Performing Start-Up: Name______________________________ Employer:_____________________________
Complete equipment data from measurements taken at the locatons indicated on the drawing below.
Equipment Data
Flow Rate EWP - LWP = ∆P
EWP-PSIIn_________________minus LWP-PSIOut __________ equals∆P____________
TherststepinndingGPMistosubtractleavingwaterpressurefromenteringwaterpressure.Thedifferencebetweenthetwo
isreferredtoas∆P.∆PcanbeconvertedtoGPMbylookingintheequipmentspecicatoncatalog.Caution ∆P ≠ GPM
Note: A conversion table must be used to nd GPM from (Delta) ∆P measurements.
Loop Fluid Temperature Rise/DropthroughCoaxialHeatExchanger EWT - LWT = ∆T
EWT-°FOut_________________ minus LWT-°FOut__________________ equalsFluid∆T _______________
∆TistheriseordropintheuidtemperatureasitpassesthroughtheCoaxial.
Air Temperature Rise/Dropthroughtheaircoil ∆T x CFM x 1.08 = BTUH Sensible
EAT-°FIn___________________ minus LAT-°FOut___________________ equalsAir∆T_________________
Note: Perform Check, Test and Start-Up in the Cooling Mode Only.
EWT- EnteringWaterTemperature EWP- EnteringWaterPressure EAT- EnteringAirTemperature ∆-Delta(Differential)
LWT - LeavingWaterTemperature LWP - LeavingWaterPressure LAT - LeavingAirTemperature CFM - CubicFeet/Minute
BTUH- BritishThermalUnits/Hour
A
I
R
C
O
I
L
V
V
V
V
V
V
Discharge
HotGas
Suction
Compressor
Reversing Valve
V
COAX
IN OUT
LWP
LWT
Loop Fluid Pressure (In PSI) EWP
Loop Fluid Temperature °F EWT
EAT
Air Temperature °F
LAT
IN
OUT
Expansion
Valve
Check, Test & Start
1
3
2
4
5 6
1 2
3
4
5
6
Form No. ____________________________