Model noMenClature
Category Code Item Code Option Code Designation & Description
Product Category 01 1 W = WaterSourceHeatPump
Product Identier 02 2-4 VFC = R410A,FloorMounted,StandardRange
VFW = R410A,FloorMounted,GeothermalRange
Design Series (Vintage) 03 5 1 =A Design
2 = BDesign
3 = CDesign
4 = DDesign
Nominal Capacity 04 6-8 009 = 9,000BtuhNominalCooling
012 = 12,000BtuhNominalCooling
015 = 15,000BtuhNominalCooling
019 = 19,000BtuhNominalCooling
024 = 24,000BtuhNominalCooling
030 = 30,000BtuhNominalCooling
036 = 36,000BtuhNominalCooling
042 = 42,000BtuhNominalCooling
048 = 48,000BtuhNominalCooling
060 = 60,000BtuhNominalCooling
070 = 70,000BtuhNominalCooling
Controls 05 9 B=MicroTech®IIIUnitController
C = MicroTechIIIUnitControllerw/LonWorks® Communication Module
D=MicroTechIIIUnitControllerw/BACnet®CommunicationModule
F = MicrotechIIIUnitControllerw/BACnetCommModule-WSHPSystem
Voltage 06 10 A=115-60-1(Sizes007-012only)
E = 208-230/60/1
J = 265/277-60-1
F = 208-230/60/3
K = 460/60/3*
L = 575/60/3
Return Air 08 12 L = Left
R = Right
Discharge Air 09 13 T = Top
Blower Motor 10 14-15 04 = ECM
Construction Type 12 18 B = Standardw/2"FilterRack
C = Standardw/CompressorSoundBlanket
D = Standardw/CompressorSoundBlanketand2"FilterRack
F = IndoorAirQuality(IAQ)w/2"FilterRack
G = IndoorAirQuality(IAQ)w/CompressorSoundBlanket
H = IndoorAirQuality(IAQ)w/CompressorSoundBlanketand2"FilterRack
Heating Options 14 20 A = 5.0kWElectricHeat
B = 10.0kWElectricHeat
Dehumidication 15 21-22 AA = HotGasReheatCoil
Desuperheater 19 30-32 DSH = Desuperheater
Refrigerant 20 33 A = R410A
Cabinet Electrical 22 35-37 75VA = 75VAControlTransformer
Water Flow Control 23 38 C = 2-WayMotorized1/2"IsolationValve,GeneralClose-OffPressureN.C.
V = 2-WayMotorized1/2"IsolationValve,GeneralClose-OffPressureN.O.
H = 2-WayMotorized1/2"IsolationValve,HighClose-OffPressureN.C.
D = 2-WayMotorized3/4"IsolationValve,GeneralClose-OffPressureN.C.
K = 2-WayMotorized3/4"IsolationValve,GeneralClose-OffPressureN.O.
J = 2-WayMotorized3/4"IsolationValve,HighClose-OffPressureN.C.
Color 24 39 A = AntiqueIvoryPre-Paint
Y = None
Notes: * A 460 volt, 3-phase unit that utilize an ECM fan motor will need a 4-wire WYE voltage supply with 3 hot leads and
a neutral wire. To power the ECM motor with neutral and one hot for 277/60/1 voltage to the ECM motor.
IM 930-6 EnnityVerticalWaterSourceHeatPumps 4 www.DaikinApplied.com