ESIE98–06A The Controller for the EUWA/Y15-30HC(Z) Chillers
Part 2 Functional Description 2–29
3
2
4
5
1
3.5 Menu Overview
An overview of the menus is given in the table below.
1
: You can assign password protection to the set points menu (see page 2-34)
Menu key Access Screen n° Task description See page
a Read-out direct Screen 1 To consult the settings. page 2-31
Screen 2 To consult the outlet water temperature. page 2-31
Screen 3 To consult the circuits status. page 2-31
z Set points direct or
password
1
Screen 1 To consult and adjust the cooling/heating set points. page 2-32
e User settings password Screen 1 To select remote control. page 2-33
Screen 2 To adjust the manual settings. page 2-33
Screen 3 To adjust the thermostat settings. page 2-34
Screen 4 To adjust the BMS settings. page 2-34
Screen 5
To assign password protection to the set points menu
1
.
page 2-34
Screen 6 To adjust the sensor accuracy. page 2-35
r Timers direct Screen 1 To read the actual value of the general timers. page 2-36
Screen 2 To read the actual value of the compressor timers. page 2-36
t History direct Screen 1 To read the unit safety information after a shutdown. page 2-37
Screen 2 To read the safety information of circuit 1 (after a shutdown). page 2-37
Screen 3 To read the safety information of circuit 2 (after a shutdown). page 2-37
Screen 4 To read the safety information of circuit 3 (after a shutdown). page 2-37
y Info direct Screen 1 To consult the unit information. page 2-38
Screen 2 To consult additional unit information. page 2-38
u Input/output direct Screen 1 To read the activated safeties. page 2-39
Screen 2 To read the status of the remote cool/heat and flow switch. page 2-39
Screen 3 To read the status of the defrost switch. page 2-39
Screen 4 To read the status of the dual set point switch, the remote
start/stop and the reverse phase protector.
page 2-39
Screen 5 To read the status of the compressors. page 2-39
Screen 6 To read the status of the low pressure bypass switch. page 2-40
Screen 7 To read the status of the fan speed relay. page 2-40
Screen 8 To read the alarm and operation indication and the status of
the pump contact.
page 2-40
Screen 9 To read the status of the reversing valve. page 2-40
q Password password Screen 1 To change the password. page 2-41