Indoor Unit SiENBE04-512A
146 Removal Procedure
1.3 Removal of Horizontal Blade and Vertical Blade
Procedure Warning Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1. Remove horizontal blade.
1
Lift horizontal blade to
open position.
Screw stoppers inside the
flap which were equipped in
the existing models are not
provided.
2
Disengage horizontal
blade from blade
retaining section.
3
Bend blade slightly and
remove it from the unit.
SiENBE04-512A.book Page 146 Friday, October 5, 2007 1:49 PM