182 Removal Procedure
3. Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
3.1 Removal of External Panels
Procedure Warning Be sure to turn off all power supplies at least 10 min. before
disassembling work.
Step Procedure Points
1. Remove the external
panels.
The top panel is integrated
with the front panel.
1
The stop valve cover
can be detached by
removing the screw.
The cover has hooks at the
right and left. Detach the
cover by sliding it downward.
Front panel
Top panel
Handle
(R4424)
Stop valve cover
(R4426)
SiENBE04-512A.book Page 182 Friday, October 5, 2007 1:49 PM