Specifications SiENBE04-512A
12 Specifications
1.1.2 Standard Grade Models
50Hz 230V
Note: MAX. interunit piping length: 15m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Models
Indoor Units FTKS20CVMB(9) FTKS25CVMB(9)(8) FTKS35CVMB(9)(8)
Outdoor Units RKH20CVMB7 RKH25CVMB7 RKH35CVMB7
Capacity
Rated (Min.~Max.)
kW 2.0 (1.3~2.6) 2.25 (1.3~3.0) 3.15 (1.4~3.8)
Btu/h 6,800 (4,450~8,850) 7,650 (4,450~10,250) 10,750 (4,750~12,950)
kcal/h 1,720 (1,120~2,240) 1,940 (1,120~2,580) 2,710 (1,200~3,270)
Moisture Removal L/h 0.9 1.2 1.7
Running Current (Rated) A 3.3 3.7 4.9
Power Consumption
Rated (Min.~Max.)
W 620 (430~945) 700 (430~1,200) 1,045 (460~1,425)
Power Factor % 81.7 82.3 92.7
COP (Rated) W/W 3.23 3.21 3.01
Piping
Connections
Liquid mm φ 6.4 φ 6.4 φ 6.4
Gas mm φ 9.5 φ 9.5 φ 9.5
Drain mm φ18.0 φ18.0 φ 18.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Indoor Units FTKS20CVMB(9) FTKS25CVMB(9)(8) FTKS35CVMB(9)(8)
Front Panel Color White White White
Air Flow Rate
m³/min
(cfm)
H 7.7 (272) 7.7 (272) 7.7 (272)
M 5.9 (208) 5.9 (208) 6.0 (212)
L 4.2 (148) 4.2 (148) 4.4 (155)
SL 3.6 (127) 3.6 (127) 3.8 (134)
Fan
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Output W 18 18 18
Speed Steps 5 Steps, Silent, Auto 5 Steps, Silent, Auto 5 Steps, Silent, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.18 0.18 0.18
Power Consumption (Rated) W 40 40 40
Power Factor % 96.6 96.6 96.6
Temperature Control Microcomputer Control Microcomputer Control Microcomputer Control
Dimensions (H×W×D) mm 273×784×195 273×784×195 273×784×195
Packaged Dimensions (H×W×D) mm 258×834×325 258×834×325 258×834×325
Weight kg 7.5 7.5 7.5
Gross Weight kg 11 11 11
Operation
Sound
H/M/L/SL dBA 38 / 32 / 25 / 22 38 / 32 / 25 / 22 39 / 33 / 26 / 23
Sound Power H dBA 56 56 57
Outdoor Units RKH20CVMB7 RKH25CVMB7 RKH35CVMB7
Casing Color Ivory White Ivory White Ivory White
Compressor
Type Hermetically Sealed Rotary Type Hermetically Sealed Rotary Type Hermetically Sealed Rotary Type
Model 5RS092XDH01 5RS092XDH01 5RS092XDH01
Motor Output W 650 650 650
Refrigerant
Oil
Type RB68A RB68A RB68A
Charge L 0.320 0.320 0.320
Refrigerant
Type R-410A R-410A R-410A
Charge kg 0.79 0.79 1.01
Air Flow Rate
m³/min
(cfm)
H 29 (1,025) 29 (1,025) 27.5(972)
L — (—) — (—) — (—)
Fan
Type Propeller Propeller Propeller
Motor Output W 25 25 25
Running Current (Rated) A 3.12 3.52 4.72
Power Consumption (Rated) W 580 660 1,005
Power Factor % 80.8 81.5 92.6
Starting Current A 3.3 3.7 4.9
Dimensions (H×W×D) mm 560×695×265 560×695×265 560×695×265
Packaged Dimensions (H×W×D) mm 599×824×337 599×824×337 599×824×337
Weight kg 31 31 33
Gross Weight kg 36 36 38
Operation
Sound
H / L dBA 46 / — 46 / — 48 / —
Sound Power H dBA 61 61 63
Drawing No. 3D048313 3D048314 3D048315
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
7.5m
SiENBE04-512A.book Page 12 Friday, October 5, 2007 1:49 PM