EasyManua.ls Logo

Daikin One+ - How to Configure Heat Kit

Daikin One+
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
» Navigate to heater kit size sub-menu
under the Air Handler
Insxtaller Wizard > equipment
setup > air handler > heater kit >
size (kW) >
Select the heater kit
size by scrolling available ‘size(kW)’
options.
» If required, adjust ‘electric heat
airflow trim’
Installer Wizard > equipment setup
> air handler > heater kit > electric
heat airflow trim
Some details have advanced settings.
How to Configure Heat Kit
Heater kit configuration varies based on the type of the Indoor units.
» Use dip switches on the board to
configure the heater kit size. Please
refer to the installation manual
of these boards to locate the dip
switches.
» Heater kit size configured with
dip switches will appear under
Installer Wizard > equipment setup
> air handler > heater kit > size (kW)
Enable ‘heater kit installed’ checkbox.
Installer Wizard > equipment setup
> air handler > heater kit installed
» ‘heater kit’ sub-menu
appears on enabling ‘heater
kit installed’ checkbox
» Inside ‘heater kit’ sub-menu ‘heat
airflow trim’ value can be adjusted
DVPEC/DVFEC
DVPVC, DVPTC, MBVC
Begin Set-up / Equipment Set-up (cont'd)