Spyder3 GigE Vision User Manual
03-032-20027-02 DALSA
32
Min 300 Hz, Max 18500 Hz
BinningHorizontal sbh set binning horizontal
Min 1, Max 2
BlackLevelRaw
[BlackLevelSelector]
sao set analog offset ti 0-1:0-255
BlackLevelSelector Black level tap selector
CalculateAnalogCameraGain
[CameraGainAlgorithmSelector]
ccg Calibrates the analog gain
1 and 2k models only
CalculateDigitalCameraGain Calibrates the digital gain so that the average pixel in the ROI is
equal to the specified target value (i.e.
CalculateCameraGainTargetValue).
CalculateDigitalCameraGainTarget The target of the digital gain calibration algorithm
CalculatePRNUAlgorithmTargetVa
lue
cpa Performs PRNU calibration according to the selected algorithm
selector (1-3)
Min 1024, Max 4055
CalculatePRNUCoefficients Calculates the PRNU coefficients using the
CalculatePRNUAlgorithmTargetValue
CalculateCameraGainTargetValue ccg The target of the analog gain calibration algorithm
Min 1024, Max 4095
1 and 2k models only
CalculatePRNUAlgorithm
CameraGainAlgorithmSelector
CameraTemperatureAbs vt verify temparature. Camera temparature.
CameraVoltageAbs vv verify voltage. Camera voltage.
CorrectionCalibrateFPN ccf NOTE: this feature will be available soon. Performs FPN
correction and eliminates FPN noise by subtracting away
individual pixel dark current.
CorrectionCalibratePRNU ccp NOTE: this feature will be available soon. Performs PRNU
correction and eliminates the difference in responsivity between
the most and least sensitive pixel creating a uniform response to
light.
DALSAExposureMode sem Exposure mode used in DALSA cameras (2-8)
DeviceModelName gcm
DALSATestImageSelector svm set video mode. Test image selection
DeviceReset rc NOTE: this feature will be available soon. reset camera
DeviceSerialNumber gcs get camera serial number. Returns the camera's serial number.
DigitalGainRaw
[GainSelector]
ssg set system gain to 0-1:0-65535
DigitalOffsetRaw
[DigitalOffsetSelector]
sdo set digital offset 0-2048
DigitalOffsetSelector DigitalOffsetSelector = {All = 0, Tap1 = 1, Tap2 = 2}
EnablePixelCoefficients epc Enables and disables FPN and PRNU coefficients.
EndOfLineSequence els end of line sequence
ExposureTimeAbs set Set exposure time in uSec (exposure mode must bt 2,6,8)
Min 3, Max 3300
GainAbs
[GainSelector]
sag Analog gain
1 and 2k models only
GainSelector The tap selector for the gain.
GPIOInput
[GPIOSelector]
sgi set GPIO input. Sets GPIO input signals.
GPIOOutput sgo set GPIO output. Sets GPIO output signals.