Spyder3 GigE Vision User’s Manual
DALSA 03-032-20027-02
49
Set up the camera operating environment
(i.e. line rate, exposure, offset, gain, etc.)
Set the calibration sample size using
the command css. It is recommended that
you use the default setting.
Perform FPN calculation
Perform PRNU calculation
1.Stopalllightfromenteringthecamera.(Tip:Coverlenswithalenscap.)
2.Verifythattheoutputsignalleveliswithinrangebyissuingthecommand
 or .Iftherearetoomanyzerosintheoutputdata(morethan6.25%
ofoutputdatawithintheroi),
increasetheanalogoffset()orusethe
automatedalgorithm .Iftheaverageofthepixelsistoohighforyour
app lication,reducetheanalogoffsetorgainlevel().
3.Issuethecommand .ThecamerawillrespondwithOK>(ifnoerroroccurs).
FPNcalculationautomaticallycalibratesFPN
coefficientsanddigitaloffset.
4.Afterthecalibration is complete,youshouldsavethesesettingstononvolatile
memorysotheybereusableonreboot.Todoso,issuethecommandsand
 .
5.Toverifyoutput,enabletheFPNcoefficientsusingthecommand .
Youshouldseeclosetozero
output.
gl gla
sao
cao0
sag
ccf
wfc
wus
epc10
i
1.Placeawhitereferenceinfrontofthecamera.
2.Verifythattheoutputsignalleveliswithinrangebyissuingthecommand
or .Ifthesignallevelistoolow,increaseyourlightlevel,adjusttheanalog
gain()orusetheautomatedalgorithm .
DALSArecommendsa
targetvalueofab out80%ofsaturation.Ifyouchange
thegain,FPNcoefficientsshouldberecalculated.
3.Issuethecommand .ThecamerawillrespondwithOK>(ifnoerroroccurs).
4.Afterthecalculationiscomplete,youcansavethesesettingstononvolatile
memorysotheywill
berememberedafterpowerdow nanddirectionchange.
Todoso,issuethecommandsand
5
gl
gla
sag ccgi0i
ccp
wpc wus.
.Enablethecoefficientsusingthecommand, .
epc11
PerformPRNUcalculationnexttodeterminethemultiplication
factorsrequiredtobringeachpixeltotherequiredvalue(balancetarget)for
flat,whiteoutput.
Set the region of interest to include all
of the image’s pixels of importance using
the command roi x1 y1 x2 y2. You can use
the default if you want to calibrate all pixels.
Note: All commands listed above are described in detail in the following sections in the order
that they should be performed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Spyder3 SG-11-01k80-00-R and is the answer not in the manual?

Dalsa Spyder3 SG-11-01k80-00-R Specifications

General IconGeneral
BrandDalsa
ModelSpyder3 SG-11-01k80-00-R
CategorySecurity Camera
LanguageEnglish

Related product manuals