MP1 charge pump torque information
Charge pump removal (38/45 shown)
P108949
K100
K300
K500
K400
K200
Identification and torque
Item Wrench size Torque
Screw (K300) 8 mm internal hex 111 N•m [81.9 lbf•ft]
MP1 charge pump inspection
Inspect the components for wear, scratches or pitting. Scratches on these components will cause a
loss of charge pressure. If any component shows signs of wear, scratching or pitting, replace it.
MP1 charge pump assembly
1. Lubricate and install charge pump (K400).
2. Install coupling (K500).
3. Lubricate and install a new O-ring (K200).
4. Install cover/aux pad (K100).
5. Install screws (K300). Torque screws per table.