MP1 CPRV torque information
CPRV valve removal (38/45 shown)
V100
QV110
V200
V300
V400
P108951
Identification and torque
Item Wrench size Torque
CPRV Valve (V100) 1 inch 78.6 N•m [58.0 lbf•ft]
CPRV inspection
Inspect washer, spring, and seat. Replace charge pressure relief valve if damage is found. Inspect the
sealing surfaces of the pump for nicks or scratches.
MP1 CPRV assembly
1. Install seat (V400), spring (V300), and washer (V200) into the housing.
2. Install new O-ring (QV110) onto the valve nut (V100).
3. Install valve nut in housing. Torque per table.
Service Manual
MP1
Minor repair
60 |
©
Danfoss | April 2019 AX00000244en-000201