EasyManua.ls Logo

Danfoss PVG 256

Danfoss PVG 256
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PVG 32 plug orientation
The PVG 32 series has increasing L port sizes with higher PVB numbers.
In particularly exposed applications, protection in the form
of screening of the electrical actuator is recommended
*85[3.3]
*170[6.7]
*170[6.7
]
*85[3.3]
PVP/PVSI:
Max. 40 Nm
[354 lbf•in]
PVS:
Max. 20 Nm
[177 lbf•in]
Number of PVB 32 1 2 3 4 5 6 7 8 9 10 11 12
L1 mm 82 130 178 226 274 322 370 418 466 514 562 610
[in] [3.23] [5.12] [7.01] [8.90] [10.79] [12.68] [14.57] [16.46] [18.35] [20.24] [22.13] [24.02]
L2 mm 141 190 238 287 335 384 432 481 529 578 626 675
[in] [5.55] [7.48] [9.37] [11.30] [13.19] [15.12] [17.01] [18.94] [20.83] [22.76] [24.65] [26.57]
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018 AX284661889190en-000101 | 25