EasyManua.ls Logo

Danfoss PVG 256

Danfoss PVG 256
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PVE series 7 for PVG 32
Assembling the PVE requires close attention.
5 [0.2]
8 ± 0.5 N·m
[70 ± 4.4 lbf·in]
PVEO/M/A Series 7
5 [0.2]
8 ± 0.5 N·m
[70 ± 4.4 lbf·in]
PVEH/S Series 7
P109120
Be sure to protect LVDT pin if present and ensure O-rings and gaskets are in place during installation. Do
not over torque.
PVEA is not compatible with PVG 100 High Flow.
PVE series 7 for PVG 32 connector overview
1 x 4 DEUTSCH 2 x 4 DEUTSCH 1 x 6 DEUTSCH
2 3
41
2 3
41
23
4 1
1
2
3 4
5
6
1 x 4 AMP 2 x 4 AMP 1 x 6 AMP 1 x 4 DIN
2418
1
2
3
4
1
2
3
4
1
2
34
5
6
1 2
3
4
PVEO-DI 4-pin AMP Connector
Pinout Pin 1 Pin 2 Pin 3 Pin 4
2x4 AMP (A) U
DC
_A U
DC
_B GND GND
2x4 AMP (B) DI-B DI-A GND U
DC2
Service and Parts Manual
PVG 16/32/128/256
Installation
34 |
©
Danfoss | October 2018 AX284661889190en-000101

Table of Contents

Other manuals for Danfoss PVG 256

Related product manuals