PVED-CC series 5 for PVG 32 technical data
PVED-CC control specification
Description Type Value
Supply Voltage (UDC) Nominal 11 to 32 VDC
Minimum 9 V
Maximum 36 V
Current consumption @ 12 V 560 mA
@ 24 V 300 mA
Power consumption @ 12 V 6.2 W
@ 24 V 7.2 W
PVED-CC operating conditions
Description Type Value
Pilot Pressure Nominal 13.5 bar [196 psi]
Minimum 10.0 bar [145 psi]
Maximum 15.0 bar [218 psi]
Oil Consumption Neutral 0 l/min [0 US gal/min]
Locked Position 0 l/min [0 US gal/min]
Actuating 0.7 l/min [0.184 US gal/min]
Storage Temperature Ambient -40 to +90°C [-40 to +194°F]
Operating Temperature Ambient -30 to +60°C [-22 to +140°F]
Oil Viscosity Operating Range 12 – 75 cSt [65 – 347 SUS]
Minimum 4 cSt [39 SUS]
Maximum 460 cSt [2128 SUS]
Oil Cleanliness Maximum 18/16/13 (according to ISO 4406)
Grade of enclosure IP 66